GB 50736-2012 第3.0.5条 Code for Design of Heating, Ventilation and Air Conditioning of Civil Buildings

Outdoor design calculation parameters暖通空调

GB 50736-2012 第3.0.5条

| The daily mean outdoor temperature for summer air-conditioning design shall be the daily mean temperature not guaranteed for 5 days on average over the years; the hourly outdoor temperature for summer air-conditioning design shall be determined in accordance with Appendix B of the code.