ME HotelM&E AI
Home › Standards › GB 50034-2013 › 第5.2.1条

GB 50034-2013 第5.2.1条 Architectural Lighting Design Standard

Illuminance standard values电气工程

GB 50034-2013 第5.2.1条

| **** | **Hotel building lighting standard values**: Guest room (general activity area) illuminance standard value **75 lx**, reference plane 0.75 m horizontal plane, color rendering index **Ra≥80**; Guest room (bedside reading) illuminance standard value **150 lx**, reference plane 0.75 m horizontal plane (local lighting), color rendering index **Ra≥80**; Guest room (writing desk) illuminance standard value **300 lx**, reference plane 0.75 m horizontal plane (local lighting), color rendering index **Ra≥80**; Guest room (bathroom) illuminance standard value **150 lx**, reference plane 0.75 m horizontal plane, color rendering index **Ra≥80**. |

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.