ME HotelM&E AI
Home › Standards › GB 50016-2014 (2018年版) › 第5.5.21条

GB 50016-2014 (2018年版) 第5.5.21条 Code for Fire Protection Design of Buildings

Building construction消防工程

GB 50016-2014 (2018年版) 第5.5.21条

| The clear width of evacuation doors of rooms in public buildings shall not be less than 0.90 m, and the clear width of evacuation corridors and stairs shall not be less than 1.10 m. In high-rise hotel buildings, the clear width of each evacuation stair shall not be less than 1.20 m. In hotel buildings, the clear width of the evacuation door of each room shall not be less than 0.90 m, and the total width of each safety exit shall be determined by calculation but shall not be less than 1.10 m.

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.