ME HotelM&E AI
Home › Standards › GB 50016-2014 (2018年版) › 第5.5.21条

GB 50016-2014 (2018年版) 第5.5.21条 Code for Fire Protection Design of Buildings

Civil buildings消防工程

GB 50016-2014 (2018年版) 第5.5.21条

| The total net width of the room evacuation doors, safety exits, evacuation walkways and evacuation stairs on each floor of a public building shall be determined based on the number of evacuees, calculated at not less than 1.00 m per 100 persons. In high-rise hotel (hotel) buildings, the number of evacuees in the guest room portion shall be calculated at 2 persons per guest room; other portions shall be calculated by multiplying the floor area of each floor by the occupant density, with the occupant density taken as 0.5–1.0 persons/m².

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.