ME HotelM&E AI
Home › Standards › GB 50016-2014 (2018年版) › 第5.5.17条

GB 50016-2014 (2018年版) 第5.5.17条 Code for Fire Protection Design of Buildings

Civil buildings消防工程

GB 50016-2014 (2018年版) 第5.5.17条

| The straight-line distance from the evacuation door of a room directly opening onto an evacuation corridor in a public building to the nearest safety exit shall not exceed the values specified in the table below: for an evacuation door located between two safety exits, in a building of fire resistance class I or II, the distance for a high-rise hotel shall be 30 m; for an evacuation door located on both sides of or at the end of a dead-end corridor, the distance for a high-rise hotel shall be 15 m.

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.