ME HotelM&E AI
Home › Standards › GB 50015-2019 › 第3.5.9条

GB 50015-2019 第3.5.9条 Standard for Design of Building Water Supply and Drainage

Pipe material给排水

GB 50015-2019 第3.5.9条

| **** | The pipes, fittings, and valves of hotel water supply pipelines (including cold and hot water) shall have a nominal pressure rating not less than the system design working pressure. Hot water pipes and fittings shall be of the same material or a matching heat-resistant grade, and pipe connections shall use dedicated heat-fusion or press-fit connections; threaded connections are strictly prohibited (plastic pipes). |

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.