GB 50015-2019 第3.9.3条 Standard for Design of Building Water Supply and Drainage

Water feature给排水

GB 50015-2019 第3.9.3条

| The water feature pool shall be provided with a makeup water pipe, drain pipe, overflow pipe and emptying facilities; the makeup water pipe shall be provided with a backflow preventer, the diameter of the makeup water pipe shall be determined according to the maximum makeup water volume, and the makeup water flow rate should be calculated at 5%–10% of the circulation flow rate.