GB 50242-2002 第10.2.14条 Code for Acceptance of Construction Quality of Building Water Supply, Drainage and Heating Engineering

Indoor drainage给排水

GB 50242-2002 第10.2.14条

| **** | Expansion joints must be installed in plastic drainage pipes in accordance with the design requirements and locations. Where there are no design requirements, the spacing between expansion joints shall not exceed 4 m. In high-rise buildings, exposed plastic drainage pipes shall be provided with fire-stop collars or fire sleeves in accordance with the design requirements. |