GB 50314-2015 第4.5.2条 Standard for Intelligent Building Design

Design Elements弱电智能化

GB 50314-2015 第4.5.2条

| | Hotel buildings should be equipped with security protection systems, including: video surveillance (cameras in public areas with a resolution of no less than 1080P and a storage period of no less than 30 days), intrusion alarm (detectors installed at guest room windows and main entrances/exits, with an alarm response time of ≤2 seconds), and electronic patrol (patrol point spacing of no more than 50 meters). |

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.