ME HotelM&E AI
Home › Standards › GB 7588-2003 › 第14.3.1条

GB 7588-2003 第14.3.1条 Safety rules for the construction and installation of elevators

Electrical equipment电梯工程

GB 7588-2003 第14.3.1条

| **** | **Emergency operating device**: A **manual barring device** (requiring two persons to operate) shall be provided in the machine room, together with a **brake release wrench**. Hotel elevators shall additionally be equipped with an **emergency electric operation device** (operated inside the car, speed ≤0.3m/s), and this device shall be **independent of the main power supply** (e.g., battery-powered). |

Other clauses of this standard

Still have a specific question? Ask a MEP expert

12 hotel MEP experts online, answers cite standard clauses you can verify.

Ask free →

Engineering reference only — verify against project conditions and the latest codes.