GB 7588-2003 第13.1.2条

| **** | **Electrical equipment protection rating**: For electrical equipment in elevator machine rooms, pulley rooms, pits, car tops, etc., the enclosure protection rating shall be no lower than **IP2X** (protection against ingress of solid foreign objects ≥12.5 mm in diameter). If installed inside the hoistway (e.g., landing door locks, inspection boxes), it shall be no lower than **IP4X** (protection against solid foreign objects ≥1 mm in diameter). In humid areas of the hotel (e.g., beside the pool, underground garage), it shall be increased to **IP54** (dust-tight + splash-proof). |