GB 7588-2003 第6.1.4条 Safety rules for the construction and installation of elevators

Equipment room电梯工程

GB 7588-2003 第6.1.4条

| **** | The equipment room shall be provided with ventilation and heat dissipation facilities to ensure that the equipment operating temperature does not exceed **+40℃** (ambient temperature), and the temperature inside the equipment room shall not be higher than **+45℃**. If natural ventilation is insufficient, mechanical ventilation devices (such as exhaust fans) shall be installed. |