How should the rated speed and acceleration/deceleration of hotel elevators be selected? Comfort requirements

Elevator engineeringUpdated 2026-05-13

I am elevator expert Ethan Liu. This issue is critical to hotel elevator design because the rated speed and acceleration/deceleration of elevators directly determine passengers' r…

How should the rated speed and acceleration/deceleration of hotel elevators be selected? Comfort requirements

I am elevator expert Ethan Liu. This issue is critical to hotel elevator design because the rated speed and acceleration/deceleration of elevators directly determine passengers' ride experience, operating efficiency, and equipment cost. In hotels—venues with high foot traffic and high comfort requirements—improper selection can lead to passenger dizziness, complaints, or energy waste. Below I provide a detailed analysis from code requirements and engineering experience to actual cases.

1. Selection of Rated Speed


According to GB 7588-2003 Safety Rules for the Construction and Installation of Electric Lifts and GB/T 10060-2011 Code for Acceptance of Electric Lifts Installation, the rated speed must be determined based on building height, number of elevators, and usage scenarios:
Engineering experience: I once participated in a 25-floor five-star hotel project. The original design adopted 2.5 m/s, but actual measurements showed passenger queues exceeding 5 minutes during peak periods. Ultimately, it was adjusted to 4 elevators at 3.0 m/s (including 1 service elevator), and the group control algorithm was optimized, reducing the waiting time to 25 seconds.

2. Acceleration/Deceleration and Comfort Requirements


The core comfort indicators are acceleration change rate (Jerk) and peak acceleration, which must comply with the recommended values in GB/T 24474-2009 Measurement of Lift Ride Quality:
Actual case: In the renovation of a five-star hotel, the original elevator acceleration/deceleration was 1.2 m/s², and passengers complained of "dizziness." By adjusting the inverter parameters (e.g., S-curve smoothing algorithm), we reduced the peak to 0.7 m/s², set the acceleration change rate to 0.4 m/s³, and added a weighing device (GB 7588 Clause 14.2.5) to preload torque. After the renovation, passenger satisfaction increased by 40%.

3. Parameter Matching and Code Constraints


4. Comprehensive Recommendations


Summary: The rated speed and acceleration/deceleration of hotel elevators should give priority to matching peak passenger flow demand, while ensuring comfort through refined parameter settings (such as S-curves). Actual cases show that an acceleration of 0.6–0.7 m/s² combined with a change rate of 0.4 m/s³ can significantly reduce passenger discomfort.

The above are reference opinions. The actual project situation still needs further comprehensive evaluation and implementation in combination with specific operating conditions, site conditions, and other factors.