Case Analysis: Common Issues and Solutions

Case Analysis Updated 2026-04-25 0 views

This article summarizes 12 categories of typical problems in hotel MEP engineering, including poor cooling performance of HVAC systems, unstable water pressure in plumbing systems, harmonic pollution in electr…

Common Problems and Solutions: Foundational Theory and Code Framework

Common problems and solutions constitute the foundational work of hotel MEP engineering design. In the field of hotel MEP engineering, common problems and solutions involve technical standards and code systems at multiple levels. Taking GB 50736 "Design Code for Heating Ventilation and Air Conditioning of Civil Buildings" as an example, this code specifies the basic parameter requirements for HVAC system design, including indoor design temperature, humidity, fresh air volume and other fundamental indicators. Hotel guest rooms typically require a summer temperature of 24-26°C and relative humidity of 50%-60%, and a winter temperature of 20-22°C and relative humidity of 40%-50%. Regarding fresh air volume, five-star hotel guest rooms should achieve a fresh air supply of 50 m³ per person per hour in accordance with Article 3.0.2 of GB 50736. In addition, GB 50189 "Design Standard for Energy Efficiency of Public Buildings" imposes higher thermal performance requirements on the energy-efficient design of hotel buildings, such as limits on the heat transfer coefficient of the building envelope, window-to-wall ratio control, and airtightness grade. GB 50016 "Code for Fire Protection Design of Buildings" imposes mandatory requirements on the fire protection design of MEP systems, including smoke control zone division, smoke exhaust system design, and selection of fire protection power distribution cables. In high-end international brand hotel projects, owner technical specifications such as Marriott International MIDS standards, Hilton HQS standards, or InterContinental IHC standards must also be satisfied simultaneously; these owner standards typically impose more stringent performance requirements on top of national codes. For example, the Marriott MIDS standard requires guest room fresh air volume of no less than 54 m³/h·person, higher than the national standard of 50 m³/h·person; LEED certification requires hotel projects to achieve at least 20% energy savings in energy consumption compared with the ASHRAE 90.1 baseline building. Therefore, common problems and solutions in hotel MEP engineering first require the establishment of a multi-level, multi-standard composite code framework system.

Analysis of Key Technical Points of Common Problems and Solutions

In hotel MEP engineering practice, common problems and solutions involve technical points across multiple key dimensions. Taking HVAC systems as an example, core technical parameters include cooling and heating load indices, system energy efficiency ratio, hydraulic balance, and supply/return air temperature difference. Article 5.2.1 of GB 50189 specifies the minimum energy efficiency requirements for chillers, such as a COP of no less than 5.6 for centrifugal units with a rated cooling capacity greater than 1,163 kW. However, in actual engineering, because five-star hotels operate for long hours throughout the year and have a high proportion of part-load operation (typically exceeding 70%), the system coefficient of performance (SCOP) is the more critical assessment indicator. The calculation method for SCOP is: SCOP = annual cumulative cooling capacity / annual cumulative power consumption (including chillers + pumps + cooling towers). According to research data from the China Academy of Building Research, the industry benchmark SCOP for HVAC systems in domestic five-star hotels is 4.0-4.5, and the advanced level can reach 5.5-6.5. Key technical measures to achieve high SCOP include: adopting variable frequency drive technology (all pumps, fans, and cooling towers variable frequency), optimizing control strategies (pre-cooling control based on load prediction, optimal reset of cooling water temperature), and selecting high-efficiency equipment (Grade 1 energy efficiency or higher). In plumbing systems, key technical parameters include water consumption quota, water supply pressure, drainage pipe diameter and slope, etc. GB 50015 "Code for Design of Building Water Supply and Drainage" specifies a hotel guest room water consumption quota of 250-400 L/bed·day, but the specific value must be determined in actual design according to the hotel star rating and operating model. Because five-star hotels have high-water-consumption facilities such as SPA, swimming pools, and laundries, actual water consumption is typically in the range of 500-800 L/bed·day. Regarding water supply system design, the flow and head selection of domestic water pumps must consider the water requirements at the most unfavorable point; typically, the outlet pressure at the most unfavorable point in hotel guest rooms is no less than 0.15 MPa, and the pressure fluctuation of the municipal water supply inlet pipe should be between 0.25-0.45 MPa.

Practical Engineering Application Cases of Common Problems and Solutions

Applying common problems and solutions to actual hotel MEP engineering projects requires customized design based on specific project conditions and owner requirements. Taking the MEP engineering of a newly built five-star hotel as an example, the project is located in a hot summer and cold winter zone, with a building area of 45,000 m² and 350 guest rooms. In applying common problems and solutions, the team focused on the following aspects: First, determination of the load calculation method. DesignBuilder software was used for annual dynamic load simulation, replacing traditional estimation or index methods. The simulation results showed a design cooling load of 4,800 kW, while the traditional index method (estimated at 120 W/m²) gave a result of 5,400 kW, a difference of 12.5%. Using dynamic simulation avoids initial investment waste and part-load efficiency degradation caused by over-sizing. Second, system scheme comparison. Three cooling and heating source schemes were compared: water-cooled centrifugal + boiler, air-cooled heat pump, and ground source heat pump. Through technical and economic analysis, the water-cooled centrifugal + boiler scheme had the lowest initial investment (approximately 6.8 million yuan), but its 10-year life cycle cost (including operating and maintenance costs) was close to that of the ground source heat pump scheme (initial investment 9.5 million yuan). Ultimately, considering site conditions and Marriott MIDS standard requirements, the water-cooled centrifugal + boiler scheme was adopted. Third, equipment selection optimization. Based on the dynamic load distribution curve, the chiller configuration was adjusted from the originally planned 4 centrifugal units (1,350 kW each) to 3 centrifugal units (1,600 kW each), reducing the number of units, improving individual unit efficiency, and saving approximately 40 m² of plant room area. Fourth, system control strategy design. A fuzzy PID control algorithm based on load prediction was adopted to optimize the chilled water supply temperature reset strategy and cooling water temperature setpoint optimization, which is expected to improve system comprehensive energy efficiency by approximately 8%-12%.

Development Trends and Optimization Directions of Common Problems and Solutions

With technological advances and continuously improving industry standards, common issues and solutions in hotel MEP engineering are showing the following development trends: First, the level of digitalization and intelligence continues to rise. MEP system design and O&M platforms based on Digital Twin technology are beginning to be applied in high-end hotel projects, enabling virtual verification of system operating performance during the design phase. The China Academy of Building Research, together with Huawei, released the "White Paper on Digital Twin Technology for Building MEP Systems," proposing the use of sensor data to drive BIM models for real-time mapping between the physical and digital worlds. Second, low-carbon and energy-saving requirements continue to increase. The Ministry of Housing and Urban-Rural Development issued the "General Code for Energy Efficiency and Renewable Energy Utilization in Buildings" (GB 55015-2021), which mandates that the carbon emission intensity of new public buildings be reduced by more than 40% compared with the 2016 baseline. Hotels, as a high-energy-consumption building type (energy consumption per unit area is typically 2-3 times that of ordinary office buildings), face greater pressure to reduce carbon emissions. Future common issues and solutions need to incorporate full life-cycle carbon footprint analysis into design considerations. Third, demand for health and comfort is escalating. After the COVID-19 pandemic, hotel guests' attention to indoor air quality (IAQ) has increased significantly. The Ministry of Industry and Information Technology and other ministries jointly issued the "Several Opinions on Accelerating the Development of New Building Industrialization," proposing the promotion of air purification, fresh air systems, indoor environment monitoring and other technologies. Common issues and solutions for hotels need to focus on fresh air system HEPA filtration efficiency (MERV 13 or above), installation of ultraviolet germicidal devices, CO₂ concentration monitoring with linked control, and other aspects. Fourth, balancing standardization and customization. Technical standards of international hotel brands (such as Marriott MIDS 2023 Edition, Hilton HQS V5, etc.) are continuously updated, imposing increasingly higher performance requirements on MEP systems. Excellent common issues and solutions need to be optimized and adjusted on the basis of meeting brand standards, in combination with project climate characteristics, local regulatory requirements and owner investment budgets.